| RESEARCH ON MEASURING METHOD OF PERMEABILITY BY USING STORAGE-VARIABLE TRANSIENT PULSE METHOD |
|
|
|
Abstract Transient pulse method is a theoretically well-established and widely used method at home and abroad. The limitation of the method in measuring range due to its fixed apparatus storage is discussed theoretically. Storage-variable transient pulse method for permeability has been proposed. The principle,test device and procedures of the storage-variable transient pulse method have been introduced;and the repeatability is analyzed based on the repeated permeability measurements at different apparatus storages. The results show that the measured values have a good repeatability(less than 5%) and well agree with that measured by constant flow method.
|
|
Received: 07 August 2008
|
|
|
|
|
|
|