Calculation method of artificial freezing wall closure time in seepage stratum
SUN Liqiang1,SHANG Ance1,LANG Ruiqing2,MIAO Yu3
(1. School of Civil Engineering,Tianjin University,Tianjin 300072,China;2. Key Laboratory of Soft Soil Engineering Characteristics and Engineering Environment of Tianjin,Tianjin Chengjian University,Tianjin 300384,China;3. School
of Civil Engineering and Mechanics,Huazhong University of Science and Technology,Wuhan,Hubei 430074,China)
Download: PDF (2299 KB)   HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      
Abstract  To solve the problem that there is no calculation method for the design of artificial freezing wall in seepage stratum in the relevant design codes,the coupled temperature field-seepage field calculation of seepage strata was realized by using COMSOL Multiphysics finite element software. The calculation results were verified by indoor tests. The development law of the temperature field with the change of seepage velocity,freezing pipe spacing and refrigerant temperature is studied by numerical calculation. The results show that when the groundwater seepage velocity is greater than the critical velocity,the freezing wall does not cross-loop and there is a good linear relationship between the critical velocity and the freezing temperature gradient. The calculation method of the critical velocity is proposed. Referring to consolidation theory,a dimensionless closure factor is proposed. The closure factor - seepage velocity curve under different freezing pipe spacing and refrigerant temperature conditions is well fitted by using the growth function curve. On this basis,the calculation method of artificial freezing closure time under seepage conditions is established. The research results can provide reference for the design and calculation of artificial freezing construction in seepage stratum.
Key wordsnumerical analysis      freezing wall      freezing pipe spacing      refrigerant temperature      critical velocity      closure time     
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
SUN Liqiang1
SHANG Ance1
LANG Ruiqing2
MIAO Yu3
Cite this article:   
SUN Liqiang1,SHANG Ance1,LANG Ruiqing2, et al. Calculation method of artificial freezing wall closure time in seepage stratum[J]. , 2023, 42(S1): 3663-3673.
URL:  
https://rockmech.whrsm.ac.cn/EN/10.13722/j.cnki.jrme.2022.0545      OR      https://rockmech.whrsm.ac.cn/EN/Y2023/V42/IS1/3663
Copyright © 2005-2015 Edited and Published by Editorial Office for Chinese Journal of Rock Mechanics and Engineering
Sponsored by : Chinese Society for Rock Mechanics and Engineering 
Published by : Science Press 
Address: Wuhan 430071, China  Tel: (027)87199250  Fax: (027)87199250  Email: rock@whrsm.ac.cn
DESIGNED BY: Beijing Magtech Science & Technolgy Development Co.,Ltd.
鄂公网安备 42010602003581号