Abstract:The underground powerhouse of Yangfanggou hydropower station is a typical large-span and high side wall cavern group. The geological condition is complex. The stability analysis of high side wall and the rock pillar between caverns is key for cavern design. Based on in-situ test data,using boundary displacement condition regression method,the initial geostress field is constructed. The stability of surrounding rock of underground caverns is analyzed by FLAC3D. The deformation and stress characteristics,plastic zone distribution field and force of support are obtained. The integrated stability of underground powerhouse is evaluated. The study results provide scientific basis and technical advice for caverns design.
白明洲,黄润秋,王士天,等. 开挖卸荷条件下高边墙岩体变形和破坏的数值计算[J]. 中国地质灾害与防治学报,2000,11(2):34-38.(BAI Mingzhou,HUANG Runqiu,WANG Shitian,et al. Study on high side wall deformation stability of a large-spaned underground powerhouse[J]. The Chinese Journal of Geological Hazard and Control,2000,11(2):34-38.(in Chinese))